Hire Controller Position Available (Sydney, NSW) More details

DV Power BLU200A

The DV Power BLU200A is an advanced emergency/backup Battery and UPS testing system. Battery discharge tester for all types of backup Battery systems.

Manufacturer
Model number
BLU200A
Shipping details
Package 29kg 60L 40W 24H Hard Case 24kg 67L 30W 43H
Daily rates
Cost per day
$395
$355.50
$296.25
$248.85
Duration (days)
1-7
8-14
15-28
29-90
Typical Hire Periods
Cost
$2,765
$4,977
$7,465.50
$14,931
Duration
week
fortnight
1 month
2 month
All prices are ex-GST
Committing to 3, 6 or 12 months?
Call us on 1300 024 473 for fantastic long term hire rates.

Request to Hire

- +
Retrieving your quote
Cost Estimate
Hire ()
Sorry there has been an error. Please try again
We will be in touch to confirm your order

Got Questions?
Give us a call, we are happy to help.

Description

The DV Power BLU200A – BLU Series are state-of-the-art battery capacity test sets, designed for standalone use or PC-controlled operation. Leveraging advanced power electronics technology with integrated coolers and fans, the BLU Series offers a lightweight solution tailored for test engineers globally. These devices meet a wide range of standardised and customised testing procedures and provide accurate, user-friendly battery capacity tests in compliance with standards such as IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and others. The series enables tests to be performed under constant current, constant power, constant resistance, or pre-selected load profiles, even while batteries remain connected to their load.

 

Need dependable equipment for your next project? Hire now to enjoy fast delivery, flexible rental options, and expert support every step of the way. Get the right products when you need them. Secure your rental today on 1300 024 473.

Key Features

  • Test resume functionality for power supply interruptions.
  • Compatible with DV-B Win software for in-depth test analysis.
  • Expandable with BXL extra load units for larger battery banks.
  • Portable and lightweight construction starting at 12.8 kg.
  • Designed with robust NORYL casing for added durability.
  • Provides discharge in various modes (constant current, power, resistance, or customised profiles).

Specification

  • Discharge Current: Up to 340 A
  • Battery Voltage Range: Up to 500 V
  • Discharge Power: Up to 28.4 kW
  • Voltage Measurement Range: 5.25 – 500 V DC
  • Basic Accuracy: ± (0.5% of reading + 0.1 A)
  • Operating Temperature Range: 0 °C to +35 °C
  • Storage Temperature Range: -30 °C to +60 °C
  • Weight: Starting from 12.8 kg
  • Display Range: 0 – 2,999.9 A DC
  • Resolution: 0.1 A
  • Typical Accuracy: ± 0.01% of reading ± 1 digit
  • Input Impedance: > 1 MΩ
  • Case Material: NORYL, shock and scratch-proof thermoplastic
  • Measurements: DC voltage and current
  • Nominal Temperature Range: 18 °C to +28 °C

Benefits

  • Accurate Testing: Delivers precise results while adhering to industry standards.
  • User-Friendly Operation: Allows easy setup and execution through a central screen or DV-Power Win software.
  • Versatile Applications: Suitable for multiple use cases across industries like power plants, telecommunication, and substations.
  • Expandable Design: Enables connection of additional load units for larger test capacities.
  • Enhanced Safety: Features adjustable alarms and shutdown parameters to prevent excessive discharge.

Applications

When you hire the DV POWER BLU200A, you’re equipping your team with a versatile instrument capable of enhancing operational efficiency and safety across multiple applications, including:

  • Power plants — In power plants, the DV POWER BLU200A plays a critical role in maintaining and testing the integrity of D.C. back-up power systems and uninterruptible power supplies for critical systems.
  • Telecommunication systems — For telecommunication systems, this device is invaluable for testing backup power systems, including batteries and generators, guaranteeing uninterrupted service and communication flow even in power outages.
  • Generator excitation systems — The DV POWER BLU200A plays a crucial role in validating the performance and reliability of generator excitation systems, which are essential for generating electrical power and maintaining the stability of the power supply.
  • Substations — In substations, the DV POWER BLU200A is used to perform vital health checks on the battery backup and uninterruptible power supplies, which are essential for preventing equipment failure and ensuring the efficient transmission of electricity.
  • Protection and control systems — This device ensures that protection and control systems are powered reliably from their DC source and that their power supplies and storage systems are at prime capacity for stable voltage output and long run time.

FAQs

Why choose DV POWER BLU200A?

Choosing the DV POWER BLU200A for your battery testing requirements signifies opting for precision and reliability. This advanced battery tester is specifically engineered for comprehensive assessment of battery capacities, crucial for ensuring the smooth operation of power systems in sectors such as power plants, substations and telecommunications.

In addition, its user-friendly interface and robust functionality make it a preferred choice for professionals aiming to uphold system reliability and safety. By opting to hire the DV POWER BLU200A from Brandis Hire, you’re getting peace of mind with a tool that guarantees accurate and dependable battery diagnostics. Be sure to reach out to us here at Brandis Hire to learn more about the DV POWER BLU200A.

What other battery testing equipment do you offer for hire?

In addition to the DV POWER BLU200A, Brandis Hire offers a range of specialised battery testing equipment, catering to diverse testing needs:

  • FLIR T530 Thermal Camera — Beyond traditional battery testing, the FLIR T530 offers an innovative approach through thermal imaging. This camera can detect heat patterns and anomalies in battery cells, connectors and wiring, allowing for non-invasive diagnostics and early detection of potential issues.
  • Megger TORKEL 860 — Renowned for its capacity to perform discharge testing under real load conditions, the Megger TORKEL 860 is critical for determining battery systems’ operational viability and health. It simulates actual power cut scenarios to provide genuine insights into battery performance and capacity.

Resources & Downloads

Hiring with Brandis Hire is easy

1

Find your Gear (and rates)

Browse our range to find the equipment you need. Select your hire dates and get instant pricing

2

Submit a Booking Request

Provide your details and submit your hire request online in minutes. We will be in touch to confirm everything

3

Pick up or we deliver

Your gear will be prepared and ready for you to collect, or let us take care of shipping direct to you

Proudly 100% Australian Family-Owned & Operated.

Brandis Hire is here to help!

We’re here to make hiring technical equipment easy!

alarm-clock-off

No lock-in hire periods

headphones-01

4 hours FREE technical support

truck-01

Delivery and Pickup options available

heart

We care about our Customers

Download

Download full price list

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

"*" indicates required fields

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

Just added to your Hire Request!
dv-power-blu-200-a
DV Power BLU200A