Doble M4110 Leakage Reactance Tester
Leakage Reactance Module
Call us on 1300 024 473 for fantastic long term hire rates.
Description
Mechanical forces resulting from system conditions such as overcurrent or transportation can cause the transformer winding to be displaced. Once a winding becomes distorted, its ability to withstand stress is severely limited, and transformer failure is inevitable. The Doble M4110 Leakage Reactance test, also called the short-circuit impedance test, is a reliable indicator of transformer winding deformation.
The leakage reactance within a transformer is sensitive to the geometrical changes in the leakage flux path. The leakage flux path predominantly comprises spaces between the winding, within the winding and between the winding and the tank wall. The short-circuit impedance of a transformer is calculated by measuring the corresponding current of a voltage applied to the primary winding with the secondary winding short-circuited. With the secondary shorted, the current drawn by the primary is essentially due to the leakage flux.
The Doble M4110 Leakage Reactance Interface enables the M4100 Automatic Insulation Analyzer to measure the short circuit impedance of transformers, a vital tool for diagnosing winding deformation.
Operation: Via Doble M4100
Working temperature range: -10 °C … +50 °C
Operating temperature range: 0 °C … +35 °C
Nominal temperature range: 18 °C … +28 °C
Storage temperature range: -30 °C … +60 °C
Weight: 14 kg without accessories ≤ 5.5 kg incl. accessories and batteries in carrying case Case material: NORYL, shock and scratch-proof thermoplastic
Key Features
- Highly accurate measurement of transformer short circuit impedance
- Reliable diagnosis of winding deformation
- User-friendly interface for ease of operation
- Suitable for both single-phase and three-phase testing
- Rugged and durable design for field use
- Provides consistent and repeatable results
- Integrated data management for efficient analysis
- Portable design with high-impact padded transport cases available
Applications
- Electrical utilities — The Doble M4110 is essential for electrical utilities to maintain transformer health. By accurately measuring short circuit impedance, it helps in diagnosing winding deformation early, preventing potential failures and extending the transformer’s operational life. This ensures the reliability and efficiency of power distribution networks, reducing downtime and maintenance costs.
- Industrial facilities — Industrial facilities rely on the Doble M4110 to monitor and maintain their transformers. Accurate impedance measurements enable timely detection of issues, ensuring smooth operation of machinery and equipment. This helps avoid costly breakdowns and production halts.
- Commercial buildings — In commercial buildings, the Doble M4110 ensures the reliability of electrical systems by regularly checking transformer impedance. This proactive maintenance practice helps prevent power outages and equipment failures, which can disrupt business operations.
- Data centres — Data centres use this to safeguard their critical power infrastructure. Regular testing of transformers for winding deformation and impedance issues is crucial to prevent failures that could lead to significant data loss and operational disruptions.
- Maintenance service providers — Maintenance service providers utilise the Doble M4110 for comprehensive transformer testing services. The device’s portability and ease of use make it ideal for field operations, allowing service providers to offer accurate and reliable diagnostics to their clients. This ensures the longevity and efficiency of their clients’ transformer assets.
Inquire about the Doble M4110 for rent today
Brandis Hire is your trusted partner for top-quality equipment rentals. With decades of industry experience, we are renowned for our massive range, reliability and exceptional customer service. Hire the Doble M4110 from us today to enhance your project’s efficiency and accuracy. You can do so by submitting a booking request or contacting us if you need more information. Our team is here to support your needs with unmatched expertise and dedication.
FAQs
Why hire the Doble M4110?
The Doble M4110 is an essential tool for accurately measuring the short circuit impedance of transformers, which is crucial for diagnosing winding deformation. This high-accuracy, reliable device supports single-phase and three-phase testing and complies with all relevant test standards. Its user-friendly interface ensures ease of operation, while its rugged design makes it suitable for field use. With the M4110, you can extend the life of transformers, reduce the risk of failure and improve the reliability of your electrical systems.
What other insulation testers, partial discharge equipment and primary injection testing equipment do you offer for hire?
Brandis Hire offers a wide range of testing equipment to meet your needs.
Insulation testers:
Partial discharge equipment:
Transformer testers:
Resources & Downloads
Hiring with Brandis Hire is easy
Find your Gear (and rates)
Browse our range to find the equipment you need. Select your hire dates and get instant pricing
Submit a Booking Request
Provide your details and submit your hire request online in minutes. We will be in touch to confirm everything
Pick up or we deliver
Your gear will be prepared and ready for you to collect, or let us take care of shipping direct to you
Brandis Hire can help!
We’re here to help make hiring technical equipment easy!
No lock-in hire periods
4 hours FREE technical support
Delivery and pickup options available
We care about our customers
Download full price list
By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.
"*" indicates required fields
By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.