Hire Controller Position Available (Sydney, NSW) More details

Omicron MCC 210

MCC 210 partial discharge coupling unit

Manufacturer
Model number
MCC210
Shipping details
Case 45kg 91L 51W 56H
Committing to 3, 6 or 12 months?
Call us on 1300 024 473 for fantastic long term hire rates.

Got Questions?
Give us a call, we are happy to help.

Description

The Omicron MCC 210 is a partial discharge coupling unit, designed to enhance the sensitivity and accuracy of PD measurements and voltage signals in high-voltage equipment. With a high coupling capacity of 1nF or more, it ensures exceptional sensitivity in low-frequency ranges, adhering to IEC 60270 standards.

Its capability to remain PD-free up to its maximum test voltage makes it a reliable choice for testing individual devices and applications in small high-voltage labs up to 100 kV. Weighing just 11kg, it’s both portable and practical, operating seamlessly with the MPD600 system for precise diagnostics.

Key Features

  • Decouple PD measurements and voltage signals from the high-voltage potential
  • High coupling capacity of 1nF or higher for excellent sensitivity even in the low frequency range (acc. IEC 60270)
  • PD-free up to PD test voltage

Applications

The MCC 210 can be used in individual device testing and testing in small HV labs up to 100 kV. Here’s how this product can be efficiently applied and used:

  • Factory acceptance testing – For medium voltage and high voltage cables including; conductors, sheaths and shields. The MCC 210 ensures that your product is of the highest quality and free of manufacturing defects that will limit its lifespan and cause costly recalls
  • Commissioning and site acceptance testing – For medium voltage and high voltage cables including; conductors, terminations, joints sheaths and shields. 23% of all MV and HV cable failures are caused by termination and jointing faults which can be detected with the use of the MCC210, MPD 600 and a PD-free source such as the Phenix BK130/36.
  • Maintenance testing – For medium voltage and high voltage cables including; conductors, terminations, joints sheaths and shields. 57% of all MV and HV cable failures are caused by cable insulation failures, these can be detected before they fail with the use of the MCC210, MPD 600 and a PD free source such as the Phenix BK130/36. This saves unnecessary damage and costly downtime.
  • Factory acceptance testing – For medium voltage and high voltage electrical components including voltage transformers, current transformers, bushings, insulators, windings and capacitors. The MCC 210 ensures that your product is of the highest quality and free of manufacturing defects that will limit its lifespan and cause costly recalls.
  • Commissioning and site acceptance testing – For medium voltage and high voltage electrical components including voltage transformers, current transformers, bushings, insulators, windings and capacitors. The FAT may be fine but damage in freight or poor workmanship in installation can cause partial discharge faults in this equipment is insipient and hard to find taking years to present and typically in catastrophic failure, but it can be detected with the use of the MCC210, MPD 600 and a PD free source such as the Phenix BK130/36.

For partial discharge equipment, the Omicron MPD 600, Phernix BK130/36 (PD free), b2 PDTD60-2, Ultra TEV Plus 2 and Phenix 50kV PD Free HiPot also stand out for their ability to detect and analyse partial discharges accurately, ensuring the reliability and safety of electrical installations.

FAQs

Why choose the Omicron MCC 210?

Choosing the Omicron MCC 210 for hire for your testing and measurement needs ensures access to a reliable, precise and versatile tool. It stands out for its adaptability across various industries, from construction to healthcare, enabling efficient monitoring and control processes. Its user-friendly interface simplifies complex testing operations, making it accessible to professionals of all skill levels.

With its comprehensive functionality, the Omicron MCC 210 is an essential asset for ensuring quality control, safety and operational efficiency in any application.

What other high potential testers, insulation testers and partial discharge equipment do you offer for hire?

At Brandis Hire, we offer a wide range of testing and measurement equipment to suit various industry needs. For high potential testers, consider our 0-100kV HiPot and HVA60, which provide robust solutions for high-voltage testing requirements.

For insulation testing, our lineup includes the Doble M4110 and the Fluke 1663 Multifunction Installation Tester, offering precise measurements and comprehensive diagnostics.

For partial discharge equipment, the Ultra TEV Plus 2 and Phenix 50kV PD Free HiPot stand out for their ability to detect and analyse partial discharges accurately, ensuring the reliability and safety of electrical installations.

For more information about our full range of products for hire, please reach out to us.

Resources & Downloads

Hiring with Brandis Hire is easy

1

Find your Gear (and rates)

Browse our range to find the equipment you need. Select your hire dates and get instant pricing

2

Submit a Booking Request

Provide your details and submit your hire request online in minutes. We will be in touch to confirm everything

3

Pick up or we deliver

Your gear will be prepared and ready for you to collect, or let us take care of shipping direct to you

Proudly 100% Australian family-owned & operated.

Brandis Hire can help!

We’re here to help make hiring technical equipment easy!

alarm-clock-off

No lock-in hire periods

headphones-01

4 hours FREE technical support

truck-01

Delivery and pickup options available

heart

We care about our customers

Download

Download full price list

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

"*" indicates required fields

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

Just added to your Hire Request!
capture
Omicron MCC 210