Hire Controller Position Available (Sydney, NSW) More details

HVA45TD

HVA 45 TAN DELTA VLF TEST SET

Manufacturer
Model number
HVA 45 TD
Shipping details
Hardcase 62kg 57L 37W 65H DO NOT USE 1kg 1L 1W 1H
Daily rates
Cost per day
$510
$459
$382.50
$321.30
Duration (days)
1-7
8-14
15-28
29-90
Typical Hire Periods
Cost
$3,570
$6,426
$9,639
$19,278
Duration
week
fortnight
1 month
2 month
All prices are ex-GST
Committing to 3, 6 or 12 months?
Call us on 1300 024 473 for fantastic long term hire rates.

Request to Hire

- +
Retrieving your quote
Cost Estimate
Hire ()
Sorry there has been an error. Please try again
We will be in touch to confirm your order

Got Questions?
Give us a call, we are happy to help.

Description

Introducing the HVA 45 TD

The HVA 45 TD stands as the cutting-edge high-voltage test set created by b2 Electronics. This versatile and powerful device is designed to competently test a broad spectrum of medium-voltage cables and equipment. The distinguishing characteristic of the 45 TD is its ability to reach a maximum output voltage of 45kV, making it an ideal choice for evaluating cables up to 35kV.

Integrated within this compact device is the innovative Tan Delta diagnostics feature, a highly efficient solution for scrutinising the condition of cables and spotting potential issues. The TD 45’s utility is further amplified by its portability and compact design, making it a breeze to carry and employ on-site. Its rugged IP67 housing equips it to endure the rigours of daily use.

For electrical engineers and technicians requiring a reliable tool for medium voltage cable and equipment testing, the 45 TD serves as a dependable partner. Not only does it ensure the safe and reliable functioning of your electrical systems, but it also helps to unearth potential problems before they escalate.

Brandis Hire takes pride in offering the HVA 45 TD for hire across Australia. We host an extensive range of units, ensuring we cater to your specific needs. Our expert team is at hand to assist you in selecting the suitable unit and offering training on using it effectively and safely.

Discover more about the HVA 45 TD or arrange a unit hire by contacting Brandis Hire today.

 

Key Features of the HVA 45 TD:

  • Max Output Voltage: 45kV pk / 32kV rms
  • Pure Sinusoidal Output Voltage
  • High Test Load Capacity of 10μf
  • USB and Bluetooth Connectivity
  • VLF AC, DC, Jacket/Sheath, Fault Conditioning Test Modes
  • In Compliance with: IEEE400, 400.2,IEC60502-2, CENELEC HD620/621
  • Automatic, Easily Programmable Test Sequences
  • Automatic TD Evaluation
  • Reporting Software Included
  • 4.3” Color Display with Intuitive Menu Operation
  • Vacuum Bottle Testing

 

The TD 45 Key Specifications:

Input Supply Voltage 100 – 240 V 50/60 Hz

Input Supply Power: 1.2kVA

Output Voltage: (Max.) Sinewave: 0 – 45 kVpeak, 32 kVrmsDC ± 0-45 kVSquarewave 45 kV

Accuracy: ± 1%, Resolution: 0.1 kV,

Output Current: 0-60 mA, Accuracy: ± 1%, Resolution: 1 μA

Resistance Range: 0.1 MW – 20 GWΩ

Output Frequency: 0.01-0.1 Hz in Steps of 0.01 Hz (default 0.1 Hz)

Automatic: Frequency:Optimization Output Load 1 μF @ 0.1 Hz @ 32 kVrms 10.0 μF @ 0.01 Hz @ 32 kVrms 0.0 μF Maximum Capacitance*

Sheath Test Max Test Voltage: 10 kV | Trip Current: 0.1 mA – 5.0 mA

Sheath Fault Location Max Test Voltage: 10 kV | Pulse/Period: 1:3 / 4 s, 1:5 / 4 s, 1:5 / 6 s, 1:9 / 6 s

Metering Voltage and Current (True rms and / or Peak), Tan Delta Capacitance, Resistance, Time, Flashover Voltage

Tan Delta Measurement Accuracy :± 1 x 10-4. Fully Compliant with IEEE400.2Duty Cycle Continuous !Test Modes Manual & Automatic

Output Modes AC (VLF) Sinewave Symmetrical and Load-Independent Across Full Range, DC (Plus or Negative Polarity), Burn/Fault Condition or Fault Trip Mode, Jacket/Sheath Testing, Squarewave Safety

Weight: 39 kg/ 86 lbs

Dimensions 500 mm x 305 mm x 457 mm/ 19.7” x 12” x 18”

Storage Temperature: -25°C to 70°C (-13°F to 158°F)

Operating Temperature: -20°C to 55°C (-4°F to 131°F)

Humidity: 5-70% Non-Condensing

 

Hire the HVA 45 TD today

Are you in need of a reliable, powerful and innovative solution for your high-voltage testing needs? Look no further. At Brandis Hire, we offer not only the versatile HVA 45 TD for hire but a comprehensive range of VLF and other electrical test equipment. Our catalogue also includes instrumentation and general industrial test equipment, available for hire Australia-wide.

With Brandis Hire, you receive meticulously maintained equipment, along with the assurance of unrivalled customer service and expert guidance. We are committed to powering your projects with the best tools in the industry. Elevate your operations, enhance your safety standards and unlock a new efficiency level with our superior range of electrical test equipment.

Take a moment to browse our catalogue and see the difference quality equipment can make. Should you require any assistance, don’t hesitate to reach out.

Resources & Downloads

Hiring with Brandis Hire is easy

1

Find your Gear (and rates)

Browse our range to find the equipment you need. Select your hire dates and get instant pricing

2

Submit a Booking Request

Provide your details and submit your hire request online in minutes. We will be in touch to confirm everything

3

Pick up or we deliver

Your gear will be prepared and ready for you to collect, or let us take care of shipping direct to you

Proudly 100% Australian family-owned & operated

Brandis Hire can help!

We’re here to help make hiring technical equipment easy!

No lock-in hire periods

4 hours FREE technical support

Delivery and pickup options available

We care about our customers

Download

Download full price list

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

"*" indicates required fields

By entering your email address, you agree to sign up to occasional marketing communications from Brandis Hire.

Just added to your Hire Request!